CTC autosamplers for LC systems

Confused about which one is right for you? Check out a the important differences here

Brochure presenting HPLC-xt systems and some options

Feature product

HTS PAL Logo-xt

 
HTS pal

 

Flexible Configuration

Max. Sample Capacity

  • 2ml vials, up to 972 vials
  • 96/384 Deepwell plates, up to 18 plates
  • 96/384 Shallow well plates, up to 24 plates

  • Cooled Sample Storage Option

    Max. Injection Valves

  • Two 2 position 6-port valves
  • Optional 2 and 3 Valve Operation
  • Multiposition Valve Drives

  • PAL Dilutor Option

    80 cm width

    HTX PAL-xt wider model also available : 120 cm

     

    Smaller PAL systems designed for LC systems

    HTC PAL logo-xt

    LC PAL logo-xt

    HTC pal lc pal

    Flexible Configuration

    Max. Sample Capacity

  • 2ml vials, up to 648 vials
  • 96/384 Deepwell plates, up to 12 plates
  • 96/384 Shallow well plates, up to 24 plates

  • Cooled Sample Storage Option

    Max. Injection Valves

  • Two 2 position 6-port valves
  • Optional 2 and 3 Valve Operation
  • Multiposition Valve Drives

  • 50 cm width

    Fixed configuration
    no options available

    Max. Sample Capacity

  • 2ml vials, up to 216 vials
  • 96/384 Deepwell plates, up to 4 plates
  • 96/384 Shallow well plates, up to 4 plates

  • Injection Valve :

  • Single 2 position 6-port valve


  • 50 cm width

     

    Larger PAL systems designed for LC systems

    (sample preparation and fraction collection)

     

    ifc pal logo-xt analytical

    ifc pal logo-xt prep

    ifc analytical ifc prep

    Injection Side

    1 Stack holding:

  • 12 MT
  • or 6 Deepwell
  • or 324 2ml vials
  •  

    Collection Side

  • 4 Stacks holding 48MT
  • or 24 Deepwell or 1296 2ml vials
  • Injection / Wash

  • 6-port VICI Valco valve
  • 2 different wash solvents
  • Injection volume 0.1 µl - 500 µl Optional

    Thermostatted Sample Storage 4°C - 40°C

    120 cm width

    Injection Side

  • 98 2ml vials or 32 10/20ml vials
  • Collection Side, Tube sizes:

  • 1092pcs. 13x100mm (9ml)
  • 700pcs. 16x100mm (12ml)
  • 700pcs. 16x150mm (20ml)
  • 504pcs. 18x150mm (27ml)
  • 504pcs. 20x150mm (34ml)
  • 294pcs. 25x150mm (55ml)
  • optional Gilson 215 rack holder
  • I

    Injection / Wash

  • 6-port VICI Valco prep valve up to 50ml/min
  • 2 different wash solvents
  • Injection volume up to 5'000µl

    120 cm width

     

    The important differences at a glance

    HTS -- most popular model, flexible configuration, 80 cm wide
    HTC -- same as HTS but smaller (narrower range 50 cm, less samples)
    HTX -- same as HTS but larger (wider range 120 cm, more samples)
    LC -- same as HTC but no flexibility, no options (50 cm) so cheaper
    IFC -- same a HTX (120 cm) but two heads (syringes) for sample prep or fraction collection

     

     


    Lots of available options and accessories

    Dilutor option

    dilutor option set

    Sample derivatization, dilutions, spiking, standard additions

    Large dispense volume combined with small injection volume

    Accelerated wash steps, cleans syringe and valve at the same time

    Brochure

     

    DLW (dynamic load wash) option

    Clean and efficient removal of carryover in the entire flow path
    Holding loop for effective rinsing of the complete sample path
    Integrated pumps for active wash solvent delivery
    Selectable wash time for organic and aqueous solvents
    Spring loaded syringe needle positioning in needle guide – no dead volume
    Existing PAL Systems can be upgraded
    X-Type Syringe based

    Brochure

     

    MALDI (Matrix-assisted laser desorption/ionization) option

    maldi spotter

    Nano, capillary and microbore LC coupled with fraction collection onto MALDI targets or microplates
    Single device for LC separation, fraction collection and re-injection of collected fractions
    Accommodates column sizes down to 75μm and flow rates up to 300μl/min
    All major MALDI Target vendors supported
    Optional on-line matrix addition via Nano Y-connector

    Brochure

     

    Valve options

    column selector

    4 Valve Option for automated parallel LC-MS analysis


    UPLC Chromatography


    Valve Switching Modules


    Column Selector Valve

     

    Brochure presenting all 4 options here

     

    A lot of other accessories like cooling trays, wash stations and flow cells are available, see the catalogue here or contact us for more information.

     


    LabSphere
    3900 place de Java, Suite 108,  Brossard,  Quebec,  J4Y 0C4,  Canada  (450) 444-0085
    Copyright ©
    Warning: date(): It is not safe to rely on the system's timezone settings. You are *required* to use the date.timezone setting or the date_default_timezone_set() function. In case you used any of those methods and you are still getting this warning, you most likely misspelled the timezone identifier. We selected the timezone 'UTC' for now, but please set date.timezone to select your timezone. in /services/webpages/l/a/labsphere.biz/public/copyright.php on line 4